# basic structure to describe the register config
class ModbusRegisters:
def __init__(self, register, length: int):
self.register = register
self.length = length
class HeidelbergWBReadInputs:
chargingState = ModbusRegisters(5, 1) # uint16: 2=A1, 3=A2, 4=B1, 5=B2, 6=C1, 7=C2, 8=derating, 9=E, 10=F, 11=ERR
# A No vehicle plugged
# B Vehicle plugged without charging request
# C Vehicle plugged with charging request
# x1 Wallbox doesn't allow charging
# x2 Wallbox allows charging
PCB_Temperature = ModbusRegisters(9, 1) # PCB-Temperatur in 0.1 °C. int16: 325 = +32.5 °C / -145 = -14.5 °C
actualChargePower = ModbusRegisters(14, 1) # Power (L1+L2+L3) in VA uint16: 1000 --> 1kW
class HeidelbergWBReadHolding:
maxCurrent = ModbusRegisters(261, 1) # Maximal current command uint16 [0; 60 to 160] 100 = 10A
failsafeMaxCurrent = ModbusRegisters(262, 1) # FailSafe Current configuration
class HeidelbergWBWriteHolding:
standByControl = ModbusRegisters(258, 1) # Standby Function Control uint16
# 0 -> enable StandBy Funktion
# 4-> disable StandBy Funktion
maxCurrent = ModbusRegisters(261, 1) # Maximal current command uint16 [0; 60 to 160] 100 = 10A
failsafeMaxCurrent = ModbusRegisters(262, 1) # FailSafe Current configuration
# (in case loss of Modbus communication) uint16 [0; 60 to 160] 100 = 10A. Default = 0
class SolarLogReadInputs:
lastUpdateTime = ModbusRegisters(3500, 2) # Unixtime, wann das letzte Registerupdate erfolgt ist.
P_AC = ModbusRegisters(3502, 2) # Gesamte AC Leistung
P_DC = ModbusRegisters(3504, 2) # Gesamte DC Leistung
P_AC_Consumption = ModbusRegisters(3518, 2) # Momentaner Gesamtverbrauch AC